2627 E 3RD ST — all permits at this address

Install new 2-gang meter main combo panel at existing service location. One meter to supply 200A feeder to upgraded main house subpanel; second meter to supply 125A feeder to upgraded rear house (ADU) subpanel. Replace existing subpanels in both structures with new code-compliant panels. Install new feeders via existing and underground conduit pathways. Provide circuits for EV chargers at both structures. All work per current NEC and LADBS requirements. Install 4 wire feeders to both subpanel.

Status date2026-08-10
JurisdictionLos Angeles, California
SourceLos Angeles Open Data (LADBS)
Data freshnessOfficial city open data (LADBS)
View official record at LADBS Online Permit Lookup