Permits at 8353 N SEPULVEDA BLVD

25 permits on file · Los Angeles, CA · from the official municipal record

22010-20003-06290 PC Info Complete

Deferred submittal for "jewel box" (for car display) for a new auto dealership under building permit no. 22010-20000-06290. · 2026-09-11

INSTALLATION OF FIRE HYDRANT AND UNDERGROUND FIRE LINE. · 2026-09-11

[ePlan] New fire alarm system with FACP (1),FAD (9),ComD (2),CP (3) · 2026-09-10

25043-20002-03556 Corrections Issued

Plan check only. Add seismic attachment detail to sheet FP6. · 2026-09-09

22041-10001-66598 PC Approved

(EPlan) Revision to 22041-10001-66595. DELTA G. REVISED SERVICE LOAD CALCULATIONS, REVISED MTG TO SURFACE/SUSPENDED FOR FIXTURE TYPES D/DE ON LIGHTING FIXTURE SCHEDULE, REVISED LOAD FOR TAILPIPE EXHAUST ON CKTS# 7,9,11 PER EQUIPMENT INFO, REVISED CKTS# 8,10,12 AND MADE THEM SPARE, REVISED CKTS# 2,4 FOR OPEN AREA REC, REVISED CIRCUITRY AND RECEPTACLE CONFIGURATION PER NEWARCH BACKGROUND.Orginial permit is 22041-10000-66598 . · 2026-09-08

22010-20005-06290 Verifications in Progress

Def submittal to Install storage racks and stairs in mezzanine into parts department. Shelving and mezzanine are deferred from 22010-20001-06290. 1) Stairs 2) Storage Racks · 2026-09-04

26043-20000-04141 PC Approved

ADDED SHEET FP8 CONSISTING OF THE NEW PARTS MEZZANINE.(PERMIT UNDER 25043-20000-03556). · 2026-09-03

22010-20006-06290 Quality Review Completed

Supplemental to permit #: 22010-10000-06290. Removal of Internet/Leasing office and separation of break room and training room into 2 separate rooms. Replace separate M/W restrooms with 1 unisex restroom. · 2026-09-01

22044-20002-16085 PC Approved

Attn: Hagop Mertekhanian. Supplemental to permit #: 22044-20001-16085. plan check only. updates to plans per narrative. · 2026-07-15

25043-20001-03556 PC Approved

ATTN MOHAMMAD. plan check only. 6" fire service and DCDA have been changed to 8". Hydraulic calculations have been changed to incorporate the update. See FP1 for the clouded note. · 2026-07-14

PROPOSED FIVE S/F ILLUM. WALL SIGNS:ONE "GALPIN" - 2' X 11'-5 1/2" 22.92 SF 22.5' ABOVE GRADE TWO "MAZDA" WITH LOGO ABOVE - 7'-8" X 3'-11/16" AND 3'-9" X 15'-7" 63.27 SF 17.25' ABOVE GRADEONE "SERVICE" - 1'-9" X 11'-4 13/16" 19.95 SF 13.5' ABOVE GRADEONE "MAZDA" WITH LOGO ADJACENT - 3'-9" X 15'-9" 58.69 SF 13.5' ABOVE GRADE · 2026-07-02

22042-20003-28182 PC Approved

PLAN CHECK ONLY. CHANGE TO MEDIUM PRESSURE GAS SYSTEM RISER. · 2026-06-23

22010-20004-06290 Quality Review Completed

Deferred submittal for new engineered steel stairs for a new auto dealership. · 2026-06-10

Eplan: submittal for permit no. 22010-10000-06290 for new storefront for a new auto dealership. · 2026-06-02

Supplemental permit to 22010-10000-03131 for the installation of automotive service lifts; double walled above ground storage tank containing combustible liquid Class III-B and automotive tailpipe extraction system · 2026-05-27

INSTALLATION OF A NEW AUTOMOTIVE TAILPIPE EXHAUST SYSTEM.(VENTILATION FOR REST OF BUILDING UNDER SEPARATE PERMIT) · 2026-05-11

22044-20001-16085 PC Approved

Install new HVAC system including RTUs, ventilation systems, and ducts. Supplemental to permit #: 22044-20000-16085. Work associated with reduction of building size. · 2026-05-08

24041-10001-07752 PC Approved

REVISIONS TO PERMITTED SET OF PLANS: The parking structure has been removed and the remaing loads remained -supplied from different feedrs than before.((((A NEW 5000A SERVICE TO SUPPLY FOUR BUILDINGS WHICH ARE UNDER SEPARATE PERMITS AND TWO FUTURE BUILDINGSEACH OF THE FOUR BUILDINGS WILL HAVE THEIR EXISTING SWTCHBOARDS BECOME A DISTRIBUTION BOARD SUPPLYING EXISTING LOADS IN THAT BUILDING.AVAILABLE SHORT CIRCUIT CURRENT FROM THE UTILITY IS ASSUMED TO BE 100KA. · 2026-03-12

22042-20002-28182 PC Approved

supplemental plan check, plan check only. reduce the scope of work, the only affected is potable water & waste and vent. · 2026-03-07

NEW FIRE SPRINKLER SYSTEM PER NFPA 13. EXISTING 6" FIRE SERVICE METER AND EXISTING 6" DCDA BACKFLOW DEVICE. · 2026-01-02

22041-10001-66595 PC Approved

Supplemental to permit #: 22041-10000-66598. Work corresponding to reduction in building size. Request for expedited processing. · 2025-12-04

22042-20001-28182 PC Approved

PLAN CHECK ONLY. CHANGE TO GAS. · 2025-11-15

[E-Plan] New construction for a new Mazda dealership with Showroom with anew 2000A 277/480V service. Total affected area is 242508 sq.ft. · 2025-10-20

Install new plumbing system including potable water, waste/vent, and medium pressure gas systems. 2" water meter, 2" backflow device. · 2025-10-20

Install new HVAC system including RTUs, ventilation systems, and ducts. · 2025-10-17