Permits at 6844 N OAKDALE AVE

16 permits on file · Los Angeles, CA · from the official municipal record

26041-10000-07183 Permit Finaled

eplan. New Fire Alarm System, 2 story building 1FACP and 257 devices · 2026-09-01

24044-20000-09460 Permit Finaled

General HVAC. · 2026-08-19

24044-20001-09460 Permit Finaled

plan check only. update the plans to match as built. · 2026-08-19

24030-20000-04763 Permit Finaled

<ePLAN>Grading for new 2 story library and administration building (permit #24010-20000-00636) and Reflection room (permit #24010-20000-00637) Site Prep., Removal and Re-compaction to prepare the site for the new construction · 2026-08-14

Provide & install VRF condensers & fan coils · 2026-08-11

24042-20000-09850 Permit Finaled

Plumbing TI. Work includes potable water and waste/vent. 3" domestic water meter. · 2026-08-07

24042-10002-09850 Permit Finaled

SUPPLEMENTAL PERMIT TO PERMIT #24042-20000-09850 TO: ADD (1) BACKFLOW DEVICE · 2026-08-07

23041-10002-74771 Permit Finaled

Changes to 23041-10000-74771. Revised the indoor T24 calculations, updated lighting fixtures revised the power layout and circuiting accordingly new sub-panel LP added. · 2026-08-05

26041-90000-02718 Permit Finaled

Low Voltogae Network Wiring · 2026-08-05

26014-20000-02930 Quality Review Completed

(ePlan) Construct 3 new classrooms above an existing breezeway. New classrooms are connected to an existing classroom building and are connected to the existing second floor classrooms. New classroom area is 2,345 square feet. <FULLY SPRINKLERED BUILDING WITH NFPA-13> · 2026-08-03

25046-20000-01152 Permit Finaled

Hydro electric elevator. · 2026-07-30

(Eplan) chnages to approve set 23041-10002-74771 updated lighting layout out, lighting fixture schedule and title 24 calculations. · 2026-05-29

25046-20001-01152 PC Approved

Plan check only. Change the location and layout of elevator machine room. · 2026-03-16

24043-20001-03746 PC Approved

Plan check only. Revised the sprinkler head locations. · 2026-01-06

[ePlan] Updated power plan layout along with IT room requirement.Changes are clouded on sheets E3.1; E5.1 ;E5.2 · 2025-08-04

24043-20000-04670 Permit Closed

FULLY SPRINKLER A REFLECTION ROOM. SINGLE 1" FDC TO BE PROVIDED AS WELL. FW BEING SERVED FROM SITE 4" SERVICE AND BACKFLOW UNDER PERMIT #24043-20000-03746. · 2025-03-26