Permits at 4890 N CALDERON ROAD

4 permits on file · Los Angeles, CA · from the official municipal record

26041-10000-05735 Permit Finaled

(EPlan) PV1 for installation of roof mounted solar panels. PV system includes 32 modules with 32 optimizers and 1 central inverter system connected to existing main service panel. System size is 14.08kW DC/10kW AC. New Rooftop Solar Installation 10.0 KW , ( 32 ) Modules , (1) Inverters.MAIN PANEL REPLACEMENT: EXISTING 200 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER TO BE REPLACED WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER · 2026-09-04

26041-20000-33937 Permit Finaled

Main panel upgrade existing 200 main panel with 200A main breaker to be replaced with new 225A main panel with 200A breaker "COMPLY WITH DEPARTMENT ORDER effective date 02/17/2026. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE" · 2026-08-23

25041-10000-39938 Permit Closed

[ePlan] new ESS & PV System roof mount on PV1: (32) Modules of 410 W, Total: 13.12 kWdc (1) Inverter of 11500 W, Total: 11.5 kWac | ESS of 13500 W, Total: 13.5 kWh (4) StringPanel: (1) 200A (gateway), (1) 225A (sub) · 2026-07-01

26041-10001-05735 PC Approved

(EPlan) Plan check only Revision to approved set under Application 26041-10000-05735. PC by: DAGIM WOLDESENBET Scope of work includes Removing disconnect · 2026-06-08