LAX-APM Supplemental to 18014-10089-05940 to provide updated drawings reflecting Shotcrete specs for use at P1 brace columns per engineer's recommendation. No change to plot plan · 2026-09-11
Make changes to the previously approved plan. Plan chek only. Permit fees issued under 19042-10000-05095. · 2026-09-04
GRADING FOR CTA WEST STATION GENERATOR. CUT 772 CY, FILL 550 CY, IMPORT 0 CY, EXPORT 222 CY. CTA GENERATOR IS UNDER PERMIT# 19020-10000-03371. · 2026-08-26
LAX APM. NON-HILLSIDE GRADING OF 1,065 CU YD CUT AND EXPORT FOR CTA WEST STATION GARAGE SHORING OF VERTICAL CORE UNDER PERMIT No.: 20016-10000-13939. · 2026-08-26
LAX APM. NON HILLSIDE GRADING FOR 1R2 ROADWAY UNDER PERMIT No.: 19020-10000-00719. CUT 861 CU YD, FILL 686 CU YD AND EXPORT 174 CU YD. · 2026-08-26
18014-10082-05940
Verifications in Progress
**ePlan**LAX- APM**Supplemental permit for 18014-10000-05940 : multiple sign types connection at the P3 and P4 parking garages at the WCTA. · 2026-08-25
**ePlan**LAX-APM** Supplemental to WCTA Station permit (18014-10004-05940) to revise Canopy Column Beam. RBS sections of the canopy beams along gridline S9 are overstressed due to excess drift at gridline P1, ultimately causing more load to be distributed to the east side (gridline 9) of the canopy. The RBS connections on grids S9/SA and S9/SC will be reinforced with DuraFuse special steel moment frame. · 2026-07-13
**ePlan**LAX-APM** Supplemental to WCTA Station permit (18014-10004-05940) for DuraFuse special steel moment frame design. · 2026-07-13
FIRE ALARM T.I. LAX CTA WEST STATION CORRIDOR LEVEL 4 · 2026-06-17
**ePlan**LAX APM**Supplemental to permit # 18014-10000-05940 :Deferred submittal to WCTA Station for glazing infill at the ped walkway TVC at TBIT · 2026-06-11
LAX ProjectCORRIDOR IMPROVEMENT CONSISTING OF GYP. COLUMN COVERS, GYP. PARTITION WALLS, POLISHED CONCRETE FLOOR · 2026-06-10
Plan check for fire sprinkler system. · 2026-06-10
Conduit repair and/or relocation of devices due to structural work at the WCTA station. · 2026-06-09
Supplemental permit WCTA DCN 395-397 (18014-10089-05940) for the P1 steel brace frame connections to concrete Level 5 beam and shearwall below Level 4 are revised to reduce the quantity of concrete penetrations by enlarging the anchor sizes and strength , adding shear lugs and higher strength grade 100 plate in lieu of grade 65 in the steel column splice is included, and encased column support brackets · 2026-05-19
LAX-APM Electrical box extension on underside of level 4 slab due to added overhead shotcrete and FRP in DCN-394/IDC-6b at WCTA. A quantity of 221 boxes are in the affected areas. · 2026-05-06
Install Fire Sprinkler System on Level 4 and (2) Pre-Action cabinets. Below floors · 2026-05-04
Supplemental to permit # (22043-10000-00396) to change address from 401 World Way to 351 World Way · 2026-05-04
minor alterations to plumbing line connections to accomodate FRP & shotcrete installation · 2026-04-30
PLAN CHECK FOR CABLE ELEVATORS. · 2026-04-29
PLAN CHECK FOR CABLE ELEVATORS. · 2026-04-24
PLAN CHECK FOR CABLE ELEVATOR. · 2026-04-24
Installation of six moving walks. · 2026-04-24
Install 1 new floor drain · 2026-04-23
Remove & reinstall fire sprinkler branch lines at various locations to allow structural upgrades to concrete deck. Third Floorbetween Grid Lines P1 to P13 & PA to PL · 2026-04-09
REROUTE EXISTING 10" UNDERGROUND FIRE LINE (LAX APM). · 2026-03-27