24010-10002-04053
Verifications in Progress
Supplemental Permit for revisions to the original scope of work under Permit Application #24010-10000-04053. Revise the building's Construction Type from 6-stories of Type I-B over 1-story Type I-A, to 6-stories of Type III-A over 1-story of Type I-A, using CBC Section 510..5, and qualifying the 1st Floor as a Basement by raising the Grade Plane level. · 2026-09-03
revisions are clouded with delta #2 Sheet E-4;Relayouted mech room, lounge, recreation room & revised power plan accordingly.Deleted HP-4, FC-3, FC-4 Relocated door location for electrical roomSheet E-5: Revised lighting plan for relayouted mech room, lounge, recreationroom Deleted exterior light on west wall due to grading level Revised circuit # exterior light on east & south wall Sheets E-6, E-7,E-8, E-9,E-10, E-11 Added exterior lights &wirings on west& north wallAdded EF-1, Sf-1 & fire smok · 2026-08-19
Temporary Shoring for new apartment building. · 2026-08-14
Attn. Zoning Plan Check Karen Meza-Morales - Building Plan Check Manuel MontufarSupplemental Zoning Plan Check submittal for revisions to the original scope of work under Permit Application #24010-10000-04053. These are the revisions being requested: 1.) Revise the building's Construction Type from 6-stories of Type I-B over 1-story Type I-A, to 6-stories of Type III-A over 1-story of Type I-A, using CBC Section 510.5, and qualifying the 1st Floor as a Basement by raising the Grade Plane level · 2026-08-11
REVISIONS TO APPROVED PLAN UNDER #25044-10000-0516 INCLUDES REMOVAL OF UNIT, RELOCATING UNITS, AND ADDITION OF COMBO FIRE/SMOKE DAMPERS. · 2026-08-05
PLAN CHECK ONLY. REVISION TO PREVIOUSLY APPROVED PLANS TO RELOCATE FIXTURES AND WATER HEATERS. NO CHANGE IN HYDRAULIC CALCULATIONS. MINOR REVISION TO RISER DIAGRAMS ONLY. · 2026-07-22
25030-10000-03167
PC Info Complete
GRADING FOR NEW AFFORDABLE HOUSING APARTMENT BUILDING TO INCLUDE REMOVAL AND RECOMPACTION · 2026-07-17
Install 1600A 120/208V 3p 4w electrical service, distribution board, panels, power and lighting for new factory built modular dwelling units for affordable apartment building. · 2026-07-14
**100%HSAP FOR REVIEW OF FLS, GREEN, ACCESSIBILITY AND STRUCTURAL (SB330/ED1)**SUPPLEMENTAL TO 24010-10000-04053**New 7-story, 54-unit, 100% Affordable Housing apartment building, utilizing ED-1 under Density Bonus. This building is a combination of Type I-A site-built podium structure, below 6-stories of Type I-B Factory-Built Modules. **PLAN CHECK FOR FOUNDATION AND PODIUM ONLY** · 2026-07-09
Plan check for heating, venting, and air conditioning. · 2026-07-09
POTABLE WATER AND WASTE/VENT FOR SITE BUILT PORTIONS OF THE BUILDING ONLY. CONNECTION TO 3" EQUIVALENT DOMESTIC WATER METER WITH 4" RP BACKFLOW PREVENTER. · 2026-07-01