Permits at 23200 W MULHOLLAND DR

13 permits on file · Los Angeles, CA · from the official municipal record

25010-20000-00280 Verifications in Progress

eplanNew subterranean parking podium for buildings A thru E, one 3-story assisted living / memory care / independent living building (Tower A,79010 sf. and D,84115 sf ), 3-story independent living; (Tower B,72430 sf C,117280, and E, 91715 sf), 4-story independent living building with amenity spaces(Bldg D), two 3-unit single story villas (Bldg G,8780 sf, H, 645 sf), one single story villa (Bldg F, 2890 sf), 78,850 cy total export grading (123,250 cy cut / 44,400 cy fill), site walls and fe · 2026-08-26

25010-20000-01460 Verifications in Progress

eplanNew buiding (Bldg G), one single story villa , · 2026-08-26

25047-10000-00427 Verifications in Progress

eplanNew pool/spa · 2026-08-26

25020-10000-00626 Verifications in Progress

eplanShoring plan for basement parking garage under building A, B, C, D, E · 2026-08-26

25030-10000-02117 Verifications in Progress

eplanGrading - site prep and excavation for new structures per site planBF 250893 APPROVED FOR AN EXPORT OF 78,850 CUBIC YARDS. · 2026-08-26

25010-20000-01459 Verifications in Progress

eplanNew (Bldg F), one single story villa, · 2026-08-26

25010-20000-01461 Verifications in Progress

eplanNew (Bldg H), one single story villa · 2026-08-26

25042-20000-19841 Corrections Issued

+++PLEASE ASSIGN THIS APP TO MATHEW NAJERA, WHO DID PLAN REVIEW OF OTHER PLUMBING SYSTEMS FOR THESE BUILDINGS+++NEW GAS, RAINWATER AND 9 SEPARATE SUMP PUMP SYSTEMS (BUILDINGS A TO E)(Please note: Plan check fee of this application for 1 earthquake valves, 2 gas pressure regulators, 18 gas outlets and 5 sump pumps was paid under 25042-20000-14940). · 2026-06-15

25042-20000-14940 Verifications in Progress

NEW PLUMBING - POTABLE WATER, WASTE/VENT AND 8 SETS OF SEWAGE EJECTORS ONLY (BUILDINGS A TO E). A SEPARATE APP WILL BE SUBMITTED FOR GAS, RAIN WATER, ETC.+++ New plumbing system for new development permitted under 25010-20000-00280.+++ · 2026-06-11

25044-20000-08737 PC Info Complete

GENERAL HVAC WITH GARAGE EXHAUST. (4) TYPE 1 HOODS. · 2026-05-13

25044-20001-08737 Corrections Issued

+++Attention VARANT MELKONIAN++++INSTALLATION OF 2 TYPE I HOODS (HOODS #17 AND #A-49, PDF SHEET 8). · 2026-04-21

25044-20002-08737 PC Approved

Plan check only. Change from A1 to A2L refrigerant. · 2026-03-23

25041-10000-30297 Verifications in Progress

[E-Plan] INSTALL NEW ELECTRICAL SERVICE 1200A AT 4160V. EACH BUILDING WILL BE FED BY SEPARATE DISTRIBUTION BOARD SYSTEMS VARRYING BETWEEN 2000A TO 4000A AT 480Y/277V 3PH 4W. THE INDEPENDANT LIVING BUILDING WILL BE EQUIPPED WITH THEIR OWN DEDICATED UNIT PANEL FED FROM THE NEAREST DISTRIUTION BOARD FOR EACH FLOOR THAT IS CONNECTED TO THE BUILDING'S MAIN DISTRIBUTION SYSTEM. PLAN CHECK FOR POWER AND ENERGY. · 2026-03-10