Interior Alteration to (E) Single Family Dwelling to demo/install interior partitions and reconfigure floor plan layout including a new bathroom . Work per engineered design . · 2026-09-10
Whole-house rewire of existing single-family dwelling: replace all branch circuit wiring from new 200A main panel and 125A subpanel (per Permit # 26041-90000-18737), including general lighting and receptacle circuits, dedicated appliance circuits (range, dishwasher, disposal, laundry, HVAC), and hardwired interconnected smoke/CO detectors. Non-engineered wiring, less than 600 volts, existing single family dwelling. Owner-builder; licensed C-10 electrical contractor performing installation. · 2026-08-06
Add two (2) new 120V branch circuits from existing panel to exterior locationsserving an outdoor fire pit and an outdoor BBQ. Underground runs in PVC conduit atcode burial depth. GFCI-protected receptacles with weatherproof in-use covers.Non-engineered wiring, less than 600 volts, existing single family dwelling,owner-builder. · 2026-08-03
Install one (1) new outdoor shower fixture with hot/cold water supply piping anddrainage to existing sanitary sewer. Install new low-pressure gas piping with two (2)outlets serving an outdoor fire pit and an outdoor BBQ. Install private subsurfaceFrench drain / area drain system with on-site discharge only; no connection tosanitary sewer or public storm drain; no pump. Single family dwelling, owner-builder. · 2026-08-03
Service change from existing overhead service to new 200A 120/240V single-phase main panel. Relocate electric panel to right side front corner of garage per LADWP Service Planning (Work Request #3170786, ESR Diane Perez, 05/05/26). New 3'x3' clear and level workspace at panel location, plus new 125A subpanel. Owner-builder; licensed C-10 electrical contractor performing installation. No branch circuits under this permit (rewire scope will be permitted separately). · 2026-05-07
Supplemental to Permit #26044-90000-03317. Correcting scope: installed system is a 5-ton Bryant heat pump (Model 235SAN06000A, R454B, 208V/1f) with new air handler, refrigerant lines, ductwork, and 60A disconnect. Cap abandoned gas line. Ground-mounted, no structural modifications. · 2026-04-23
Trenchless rehabilitation of existing sewer lateral via Cured-In-Place Pipe (CIPP) lining through existing cleanouts. Replacement of house-to-sewer connection (tie-in) at building exterior, including new ABS/cast iron lateral pipe to existing cleanout. No change in fixture count or pipe routing. · 2026-04-16