Re-roof with Class A or B roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 7 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. · 2026-08-03
(EPlan) PV1 for installation of roof mounted solar panels. PV system includes 12 modules with 12 optimizers and 1 central inverter system connected to existing main service panel. System size is 5.28kW DC/3.8kW AC. New Rooftop Solar Installation 5.28 KW, (12) Modules, (1) Inverter · 2026-07-09
MAIN BREAKER DERATE: REPLACE EXISTING 200 AMP MAIN BREAKER WITH NEW 175 AMP 22K AIC RATED MAIN BREAKER. · 2026-07-09