PLAN CHECK FOR WASTE/VENT AND RAINWATER. INCLUDES FOX DRAIN. · 2026-09-09
26041-10000-35189
Quality Review Completed
(EPlan) PV2 for installation of roof mounted solar panels and installation of energy storage system on commercial apartment property. PV system includes 62 modules, (3) hybrid inverter system, (3) energy storage system, 200A load center, and 50KVA transformer connected to existing 800A main service panel. System size is 27.28kW DC/27.0kW AC. INSTALLATION OF A ROOF-MOUNTED SOLAR PHOTOVOLTAIC AND ENERGY STORAGE SYSTEM FOR THE REAL PROPERTY LOCATED AT 1808 S. ST. ANDREWS PLACE, LOS ANGELES, CA 900 · 2026-08-31
new trash & recycle enclosure · 2026-08-26
REVISION TO APPROVED PLANS. ADD SPRINKLER HEADS IN THE ATTIC AND TO ADD WATER CURTAIN HEADS ON AN EXISTING NFPA 13 SPRINKLER SYSTEM. 4-INCH FIRE METER WITH 4-INCH DOUBLE CHECK BACKFLOW PREVENTER. PARTIAL PERMIT FEES PAID UNDER 24043-10000-04542. · 2026-08-18
INSTALL FOX DRAIN · 2026-08-10
Supplemental submittal to 22010-10000-00571 for relocation of Elevator Machine Room at Roof to the trash room on ground floor. Trash & recycle are being relocated to the front of the building no change in occupancy · 2026-08-06
ATTN FARSHAD BACKROOM Expedited review for the addition of a 10'H x 10'L 8" Thick CMU Site wall for mounting Solar Equipment in the rear yard of the project · 2026-08-04
NEW FIRE SPRINKLER SYSTEM PER NFPA 13. INCLUDES 4" FIRE METER AND 4" BFP. · 2026-07-13
Inspection of installation of 4 inch underground fire pipe sweep prior to plan check · 2026-06-17
200A temp power pole. · 2026-06-03
Voice,Data,CCTV and Two way · 2026-05-29
(Eplan) Delta 15 clouded changes only. Updating site plan to relocate panels and switch + updated single line diagram to match on site condition per inspector request. New inverter and circuits · 2026-05-29
Temporary Generator · 2026-05-29
Installation of (1) Traction elevator. · 2026-05-19
[E-Plan] Expedited review of Single line Diagram updated to reflect relocation of Elevator machine room from roof to ground floor. This is a continuation to 22041-10003-17899. · 2026-05-08
General HVAC. · 2026-03-27
[Eplan] Plan check only. Revisions to approved set under delta 16 only. Relocation of Elevator Machine Room and all its electrical components from the Roof to the ground floor trash room. Trash room is being re-purposed into an elevator control room. New trash enclosure on exterior of building to house trash is under separate permit. No change to existing panels · 2026-03-14
FULL PLAN CHECK FOR CONVERSION OF SFD TO NEW MULTIFAMILY HOUSING. NEW 600A SERVICE, PANEL, LIGHTING, AND POWER LOADS. TOTAL SQUARE FOOTAGE = 1687 SF · 2026-01-23
[ePlan] New fire alarm system for apartment building. (1) FACP and (52) FA devices. · 2025-12-20
UNDERGROUND FIRE WATER LINE ONLY. 4" FIRE METER, 4" BACKFLOW PREVENTER. · 2025-12-19
POTABLE WATER ONLY. NEW 2-INCH DOMESTIC WATER METER. · 2025-12-17
[EPLAN] PV2 NEW ROOF MOUNTED PV SYSTEM. PV SYSTEM SIZE IS 32.6 KW DC/30 KW AC. SCOPE OF WORK CONSISTS OF (74) PV MODULES, 1 CENTRAL INVERTER, AND 1 TRANSFORMER. · 2025-09-30
PLAN CHECK ONLY, PERMIT UNDER 24043-10000-04542.REVISION TO APPROVED PLANS UNDER 24043-10001-04542 TO ADD SWAY BRACING TO 4" STANDPIPE. · 2025-07-17