Permits at 155 S BARRINGTON PL

20 permits on file · Los Angeles, CA · from the official municipal record

23016-10000-03770 CofO Issued

Existing Retail Shops Change of Use to Restaurant and Major remodel · 2026-09-08

23016-10007-03770 Permit Finaled

Supplemental to 23016-10000-03770: Update owners information · 2026-09-02

23016-10003-03770 Permit Finaled

SUPPLEMENTAL PERMIT TO 23016-10002-03770 TO CHANGE CONTRACTOR FROM GREGORY O'CONNOR (1045286) TO GERARDO RAMIREZ MORATAYA (1024154) · 2026-06-18

23016-10002-03770 Permit Finaled

Supplemental to 23016-10000-03770 Change Mezzanine layout · 2026-06-18

23016-10001-03770 Permit Finaled

Supplemental permit to 23016-10000-03770: Structural Revisions · 2026-06-18

23016-10005-03770 Permit Finaled

Supplemental to 23016-10000-03770 Added location on S-2.2 and detail 13/S-3.2 for duct penetration at mezzanine floor.Added location on S-2.2 and detail 14/S-3.2 for duct penetration at shear wall on grid line E.Added MAU#3 on Grid D3 · 2026-06-18

23016-10006-03770 Permit Finaled

Supplemental to 23016-10000-03770 for Relocation of Toilet in ADA W/C · 2026-06-12

25048-20000-00474 Permit Finaled

TWO NEW ILLUMINATED (1) 2' x 19'-3", (2) 2' x 29'-3"; WALL SIGNS · 2026-05-22

24044-10000-13750 Permit Finaled

HVAC T.I. INCLUDES (5) TYPE I HOODS AND (1) TYPE II HOOD · 2026-05-20

26044-90000-05167 Permit Finaled

New walk in cooler & freezer · 2026-05-20

26044-10000-04946 Permit Finaled

INSTALL COMPRESSORS FOR REFRIGERATOR, 3- Refridgeration<= 25HP · 2026-05-20

25042-90000-17847 Permit Finaled

INSTALLATION OF: Seismic Gas Shutoff Valve · 2026-05-12

24042-90000-17371 Permit Finaled

GAS OUTLETS & BACKFLOW DEVICES · 2026-05-12

24042-90000-12690 Permit Finaled

FURNISH & INSTALL - FLOOR SINKS, FLOOR DRAINS, GREASE TRAP & ALTER/REPAIR WASTE PIPING. · 2026-05-12

24042-90000-13962 Permit Finaled

FURNISH & INSTALL:WATER CLOSETS, TRAP PRIMERS, KITCHEN SINKS, HAND SINKS & LAVATORIES · 2026-05-07

24041-10000-27051 Permit Finaled

[ePlan] Full PC for new 600A 120/240V 3PH 4W service, sub panels, power and lighting for existing commercial building TI. Total affected area is 4850 sqft. · 2026-05-01

24041-10002-43717 Permit Finaled

field conditions and corrections Delta 545KVA Transformer now only feeds Panel BNew 75KVA Transformer feeds Panel CDishwasher D3 now fed from main serviceTotal Service Load Calculation RevisedPanel A,B,C and D Schedule Revised · 2026-05-01

24041-10001-43717 Permit Finaled

Changes to permit 24041-10000-27051, updated lighting fixture schedule and title-24. Delta 4. · 2026-05-01

24041-90000-52133 Permit Finaled

Installation of new dedicated function central station sprinkler monitoring permit. · 2026-04-24

24043-10000-03558 Permit Finaled

New fire sprinkler system per NFPA 13 with 6" fire service. · 2026-04-13