Permits at 10915 W STRATHMORE DR

16 permits on file · Los Angeles, CA · from the official municipal record

20010-10000-02544 CofO Issued

NEW 7 STORY 37 UNITS (5 VLI) AFFORDABLE HOUSING APARTMENT TO INCLUDE 5 STORY TYPE IIIA APARTMENT OVER 2 STORY TYPE IA APARTMENT OVER 2 LEVEL SUBTERRENEAN PARKING, 12.22 A.25 WITH ADDITIONAL INCENTIVES AND INCREASED DENSITY BONUS PER 12.24.U.26 · 2026-09-10

22042-10003-11468 Permit Finaled

REVISION TO APPROVED PLANS UNDER 22042-10000-11468.REVISING STORM DRAINAGE SYSTEM TO ADD 8" FIRE TANK OVERFLOW DRAINING TO SUMP AND REVISING SUMP SPECS AND SIZING. REVSING DUPLEX TO QUADPLEX SUMP PUMP SYSTEM. · 2026-08-25

24041-90000-46037 Permit Finaled

LOW VOLTAGE · 2026-08-25

22042-10000-11468 Permit Finaled

INSTALLATION OF NEW PLUMBING SYSTEM. INCLUDES POTABLE WATER, WASTE/VENT WITH DUPLEX SEWAGE EJECTOR, MEDIUM PRESSURE GAS AND RAINWATER SYSTEM WITH SUMP PUMP. 4" WATER METER WITH BACKFLOW DEVICE. · 2026-08-11

25041-10001-05919 Permit Finaled

[ePlan] Change to previous approved FA plan set (25041-10000-05919). Adding two duct dectors per inspector.***Application Note*** There was necessary minor field change that needed to be done to previously approved plans. The only changes were adding 2 Duct detectors on the 1st floor. · 2026-06-16

25041-10000-05919 Permit Finaled

[ePlan] New Fire Alarm System consisting of 1 FACP, 1 communicator, 1 annunciator, 8 power supply units and 480 FA devices. · 2026-06-16

22042-10004-11468 PC Approved

PLAN CHECK ONLY. REVISION TO PREVIOUSLY APPROVED PLAN UNDER 22042-10000-11468. REVISED STORM DRAINAGE RISER DIAGRAM · 2026-06-15

25046-10000-00924 Permit Finaled

INSTALLATION OF A CABLED ELEVATOR. · 2025-12-26

22041-10000-18944 Permit Finaled

[E-Plan] New Electrical installation for 7-Story low rise, 37-unit affordable housing apartment. 2 services one at 1600A,120/208,4w, 3ph and 1200A,120/208,4w, 3ph. area of scope 12K+ Sqft · 2025-12-23

22041-10001-18944 Permit Finaled

[E-Plan] Deltas 2,3,4,5 and 6 clouded changes to approved set. Changes to power and energy · 2025-12-23

23043-20004-00097 PC Approved

REVISION TO APPROVED PLANS. ADDED COPIES OF MANUFACTURER'S SPECIFICATIONS FOR DELUGE VALVE 100G-UP AND FLOW LIMITING ASSEMBLY X102 ON SHEET 2 OF 14. NO OTHER CHANGES UNDER THIS PLAN CHECK. · 2025-12-11

23043-10000-00097 Permit Finaled

NEW FIRE SPRINKLER SYSTEM PER NFPA 13 WITH STANDPIPE SYSTEM, FIRE TANK, FIRE PUMP, AND CAR STACKERS. 6" FIRE METER WIITH 6" DC BACKFLOW. · 2025-11-12

23041-10000-71213 Permit Closed

PLAN CHECK FOR A NEW 800A 3P 480V 4W SERVICE AND DOWNSTREAM PANELS FOR TEMP POWER AT A NEW BUILDING. · 2025-11-05

22044-10000-05411 Permit Finaled

HVAC INCLUDING GARAGE VENTILATION AND GENTERATOR ROOM VENTILATION · 2025-10-29

24042-20000-18191 Permit Finaled

INSTALLATION OF SPA FOR APARTMENT BUILDING. · 2025-09-17

23043-10003-00097 PC Approved

Plan check only. Revisions to approved plans 23043-10002-00097.Address inspector correction notice, includes adding extended coverage spacing, addition of water curtain heads, updating CPVC sway brace calcs, and adding heads below car stackers due to trash/auto fluids. · 2025-09-08