FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101084420. AFFECTS: 0 DWELLING UNITS; 2 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 36TH & 37TH FLOOR MAGLOCKS. · 2026-09-02
FIRE ALARM: REPAIR EXISTING SYSTEM. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: BASEMENT. · 2026-09-01
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 304 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: 36TH FLOOR. · 2026-08-25
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 200 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: 37TH FLOOR. · 2026-08-25
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO EXISTING 32ND, 33RD, AND 34TH OFFICE FLOORS AS PER PLANS. WORK TO INCLUDE NEW OPEN OFFICE AND PRIVATE OFFICES, CONFERENCE ROOMS, MULTIPURPOSE ROOMS, PANTRIES, AND RENOVATION OF EXISTING CORE RESTROOMS. DEMOLITION AND CONSTRUCTION OF NON-LOAD BEARING PARTITIONS, MOVABLE PARTITIONS, DOORS AND HARDWARE, CEILINGS, LIGHTING, FINISHES, MILLWORK, AND ASSOCIATED MEP WORK. NO CHANGE IN USE. STRUCTURAL PEER REVIEW INCLUDED. LEVELS 33 & 34 B-BUSINESS, LEVEL 32 · 2026-08-06
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS IN AN EXISTING OFFICE BUILDING ON THE 9TH FLOOR TO DIVIDE OFFICE SUITE 925 INTO TWO OFFICE SUITES, 925 AND 900. WORK INCLUDES CONSTRUCTION OF A DEMISING WALL, NON-LOAD-BEARING PARTITIONS, MILLWORK, FINISHES, CEILINGS, AND ASSOCIATED ELECTRICAL, VENTILATION AND PLUMBING WORK, AS PER PLANS. (OCCUPANCY GROUP B; TYPE IA CONSTRUCTION). · 2026-07-29
TEMPORARY SCAFFOLDING: QTY: 1, MAX. LENGTH: 30 FT., MAX. HEIGHT: 40 FT. LOCATION: EXTERIOR FACADE. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT. · 2026-06-19
SELF-CERT 2019 CBRC: REVISION TO PERMIT #101079053 TO ADD SUPPLEMENTAL COOLING AND PLUMBING UPDATES. B-BUSINESS, 1A CONSTRUCTION. NO CHANGE IN USE. · 2026-06-10
SELF-CERT 2019 CBRC: ALTERATION OF INTERIOR OFFICE SUITE ON FLOOR 26 IN AN EXISTING 37 STORY BUILDING (OCCUPANCY GROUP B / TYPE 1A CONSTRUCTION) · 2026-06-09
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: SUITE 1675. · 2026-05-27
FOR PERMIT 101080231: ADDITIONAL ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. · 2026-04-22
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL TELEPHONE. SPECIFIC LOCATION: 36TH & 37TH FLOOR. · 2026-04-21
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101079053. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 36TH & 37TH FLOORS. · 2026-04-20
SELF CERT 2019 CBC: SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO THE LOBBY OF AN EXISTING HIGH-RISE OFFICE BUILDING. WORK TO INCLUDE NEW INSTALLATION OF TURNSTILES AT THE ELEVATOR BANKS(OCCUPANCY B, TYPE IA CONSTRUCTION) · 2026-03-16
SPR 2019 CBRC: INTERIOR ALTERATIONS FOR NEW SERVER ROOMS ON FLOOR 36 & 37. DEMO PERMIT UNDER #101071758. B-BUSINESS, 1A CONSTRUCTION. NO CHANGE IN USE. · 2026-02-09
SELF-CERT 2019 CBRC: STRUCTURAL PEER REVIEW INCLUCED. INTERIOR ALTERATIONS ON FLOOR 36 & 37. WORK TO INLCUDE NEW PARTITIONS, ELECTRICAL, MECHANICAL, AND PLUMBING AS PER PLANS. DEMO PERMIT UNDER #101071758. B-BUSINESS, 1A CONSTRUCTION. NO CHANGE IN USE. · 2026-02-09
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:100705426. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: TENANT ENTRY DOOR FOR SUITE 980 ON THE 9TH FLOOR. · 2026-02-03
FOR PERMIT 101074544: REPLACEMENT ELECTRICAL CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. · 2026-01-28
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101074544. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: YES. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 15TH FLOOR ELEVATOR LOBBY & RECEPTION MAGLOCK. · 2026-01-23
SELF CERT 2019 CBRC: REVISION TO PERMIT # 101074544 TO OMIT PLUMBING AND RESTROOM PARTITION WORK IN WOMENS RESTROOM.1A CONSTRUCTION. B-BUSINESS · 2025-12-15
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101074544. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: YES. SPECIAL LOCKING: NO. MONITORING TYPE: SUPERVISING STATION . SPECIFIC LOCATION: 15TH FLOOR. · 2025-12-15
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: 28TH FLOOR. · 2025-12-15
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL SECURITY. SPECIFIC LOCATION: 15TH FLOOR. · 2025-12-09
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101072159. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: NONE (EXEMPT) . SPECIFIC LOCATION: 21ST FLOOR OFFICE, SUITE 2125. · 2025-11-20
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 11/18/2025. END DATE: 11/18/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST. · 2025-11-18