*ERECTION STARTS 09-03-2026 ERCTION ENDS 09-08-2026. INSIDE WRIGLEY FIELD FOR THE WOMEN'S COLLEGE VOLLEYBALL. PERMIT FOR ONE (1) 120' × 84' PLATFORM STRUCTURE 30" (2'-6") ABOVE GROUND LEVEL AND TWO (2) RAMPS. **STRUCTURAL PEER REVIEW** · 2026-09-04
PERMIT EXPIRES ON 09/14/2026 ERECTION STARTS: 07/08/2026, ERECTION ENDS: 07/16/2026. SELF-CERT - CBC 2019 - PEER REVIEW. ERECTION OF TEMPORARY STAGE FOR A NOAH KAHAN CONCERT AT WRIGLEY FIELD, EVENT DATES JULY 14-15TH, 2026 OVERALL AREA: 13,963 SQ.FT., INCLUDING:1.) MAIN STAGE: 11,541 SF2.) FRONT OF HOUSE (FOH) MIX HUT: 24FT X 32FT = 768 SF3.) CURVED THRUST STAGES: 1,046 SF4.)B-STAGE: 16FT X 17FT = 272 SF5.) C-STAGE: 16FT X 21FT = 336 SF · 2026-07-14
PERMIT EXPIRES ON 09/10/2026 ERECTION STARTS: 07/08/2026, ERECTION ENDS: 07/16/2026. SELF-CERT - CBC 2019 - PEER REVIEW. ERECTION OF TEMPORARY STAGE FOR A JON MULANEY CONCERT AT WRIGLEY FIELD, EVENT DATES JULY 11TH, 2026 OVERALL AREA: 10,398 SQ.FT., INCLUDING:1.) MAIN STAGE: 9,630 SF2.) FRONT OF HOUSE (FOH) MIX HUT: 24FT X 32FT = 768 SF · 2026-07-10
PERMIT EXPIRES ON 09/10/2026 ERECTION STARTS: 7/8/2026, ERECTION ENDS: 7/16/2026. SELF-CERT - CBC 2019 - PEER REVIEW. ERECTION OF TEMPORARY STAGE FOR A TYLER CHILDERS CONCERT AT WRIGLEY FIELD, EVENT DATES JULY 12TH, 2026 OVERALL AREA: 11,879 SQ.FT., INCLUDING:1.) MAIN STAGE: 10,910 SF2.) FRONT OF HOUSE (FOH) MIX HUT: 24FT X 32FT = 768 SF3.) B-STAGE: 16FT DIAMETER = 201 SF · 2026-07-10
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: ASSEMBLY. START DATE: 7/14/2026. END DATE: 8/13/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST. · 2026-06-30
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: ASSEMBLY. START DATE: 7/11/2026. END DATE: 8/10/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST. · 2026-06-30
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: ASSEMBLY. START DATE: 7/12/2026. END DATE: 8/11/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST. · 2026-06-30
PERMIT EXPIRES ON 08/09/2026 ERECTION STARTS: 06/08/2026, ERECTION ENDS: 06/13/2026. SELF-CERT - CBC 2019 - PEER REVIEW. ERECTION OF TEMPORARY STAGE FOR A MUMFORD & SONS CONCERT AT WRIGLEY FIELD, EVENT DATES JUNE 11TH, 2026 OVERALL AREA: 11,184 SQ.FT., INCLUDING:1.) MAIN STAGE: 10,272 SF2.) FRONT OF HOUSE (FOH) MIX HUT: 24FT X 32FT = 768 SF3.) B-STAGE: 12FT X 12FT = 144 SF · 2026-06-12
PERMIT EXPIRES ON 08/10/2026 ERECTION STARTS: 06/08/2026, ERECTION ENDS: 06/13/2026. ERECTION STARTS: , ERECTION ENDS: . SELF-CERT - CBC 2019 - PEER REVIEW. ERECTION OF TEMPORARY STAGE FOR A RUFUS DU SOL CONCERT AT WRIGLEY FIELD, EVENT DATES JUNE 12TH, 2026 OVERALL AREA: 11,040 SQ.FT., INCLUDING:1.) MAIN STAGE: 10,272 SF2.) FRONT OF HOUSE (FOH) MIX HUT: 24FT X 32FT = 768 SF · 2026-06-12
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: WRIGLEY FIELD. · 2026-06-08
DDS 2019 CBC: REPLACEMENT OF 1 WHEELCHAIR LIFT AND NEW ACCESSIBLE SEATING PLATFORM AT SECTION 218. WORK AT SECTIONS 101, 102, 103, 104, 105, 117, 118, 119, 120, 130, 131, 132, 133, 134, 230, 231, AND 232 INCLUDES THE EXTENSION OF EXISTING ACCESSIBLE SEATING PLATFORMS, NEW ACCESSIBLE SEATING PLATFORMS AND REMOVAL OF EXISTING ACCESSIBLE SEATING PLATFORMS. (OCCUPANCY A-5; CONSTRUCTION TYPE IIB) CONSULTANT REVIEWER: V3 COMPANIES OF IL · 2026-06-05
DDS CBC 2019: THE ADDITION OF 2 WHEELCHAIR LIFTS, 1 EACH AT SECTION 6 AND SECTION 23 AT NEW ACCESSIBLE SEATING PLATFORMS IN THE LOWER SEATING BOWL PLUS AT THE CLUBHOUSE LEVEL A NEW WOMENS UMPIRE LOCKER ROOM WILL BE PROVIDED AND THE WOMENS LOCKER ROOM TO BE RELOCATED. (OCCUPANCY A-5:CONSTRUCTION TYPE 11A). CONSULTANT REVIEWER: V3 COMPANIES OF IL · 2026-04-24
INSTALLATION OF (1) ONE VERTICAL PLATFORM WHEELCHAIR LIFT BEHIND HOME PLATE, 750LBS CAPACITY @ 20FPM, 2 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION (EV011882). · 2026-02-02
INSTALLATION OF (1) ONE VERTICAL PLATFORM WHEELCHAIR LIFT BY THE 1914 MAKER'S MARK LOCATION, 750LBS CAPACITY @ 20FPM, 2 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION (EV011882). · 2026-02-02
INSTALLATION OF (1) VERTICAL PLATFORM WHEELCHAIR LIFT BY THE W CLUB LOCATION, 750LBS CAPACITY @ 20FPM, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU IINSPECTION (EV011882). · 2026-02-02
REMOVAL OF BEHIND HOME PLATE WHEELCHAIR LIFT WITH NEW ONE BEING INSTALLE3D UNDER PERMIT #101078954. · 2026-02-02
TEMPORARY STRUCTURE: NEW INSTALLATION. TENT (OPEN SIDES) - ASSEMBLY - 600 SQ. FT. ELECTRICAL WORK = NO. NON-SEWER TOILETS: 0. INSTALL DATE: 1/9/2026; REMOVAL DATE: 1/10/2026. · 2026-01-06
DDS 2019 CBC TO REPLACE A RAMP FROM THE TERRACE TO UPPER DECK. (OCCUPANCY GROUPS: A-5; TYPE 2 CONSTRUCTION. ALL AS PER PLANS CONSULTANT REVIEWER: V3 COMPANIES OF IL · 2025-12-18
SITE IMPROVEMENTS TO INSTALL SAFETY BOLLARDS ALONG THE PERIMETER OF THE STADIUM INCLUDING FIXED, REMOVABLE, & OPERABLE BOLLARDS. SCOPE INCLUDES REMOVAL OF EXISTING ASPHALT, CURB & PAVERS FOR ACCESS & INSTALLATION OF BOLLARDS & THEIR FOUNDATION WITH M.E.P., TICKET BOOTH ROOF AND PARAPET WALL REPAIRS, LOADING DOCK STRUCTURAL REPAIRS AS PER PLANS **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS ** SIGNAGE AND PUBLIC WAY WORK UNDER SEPARATE PERMITS · 2025-11-21
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: STREET. · 2025-11-20